Afficher la notice abrégée

dc.contributor.authorBouvet, Elisabeth-
dc.date.accessioned2014-07-03T06:51:22Z
dc.date.available2014-07-03T06:51:22Z
dc.date.issued2006fr_FR
dc.identifier.citationBouvet, Elisabeth ; La légionellose, Med Sci (Paris), 2006, Vol. 22, N° 6-7; p. 601-606 ; DOI : 10.1051/medsci/20062267601fr_FR
dc.identifier.issn1958-5381fr_FR
dc.identifier.urihttp://hdl.handle.net/10608/5813
dc.description.abstractBien qu’on ne retrouve pas l’origine de la contamination dans la moitié des cas de légionellose humaine, on sait que cette maladie est la conséquence de la contamination presque obligatoire des réseaux d’installations d’eau chaude par Legionella pneumophila, et l’inhalation par l’homme de gouttelettes infectées. La pathologie consiste le plus souvent en une pneumopathie relativement grave. La maîtrise du niveau de contamination des différentes installations hydriques productrices d’aérosols est impérative pour éviter les conséquences sanitaires graves, qui ne peuvent être prévenues par une action sur la cible humaine. La plupart des réservoirs actuellement identifiés sont les tours aéroréfrigérantes et les réseaux de distribution d’eau chaude. La prise en compte de ce risque dans les établissements hospitaliers ou thermaux a conduit à la mise en oeuvre de nombreuses mesures de désinfection et de contrôle, qui commencent à montrer une certaine efficacité sur la survenue de nouveaux cas dans ces établissements, aujourd’hui en nette diminution.fr
dc.description.abstractAlthough one does not find the origin of the contamination in the human half of the cases of legionellosis, one knows that this disease is the consequence of the almost obligatory contamination of the networks of installations of hot water by Legionella pneumophila, and the inhalation by the man of infected droplets. Pathology generally consists of a relatively serious pneumopathy. The control of the level of contamination of the various producing hydrous installations of aerosols is imperative to avoid the serious medical consequences, which cannot be prevented by an action on the human target. The majority of the currently identified tanks are the air and cool towers and the distribution networks of hot water. The taking into account of this risk in the hospitals or thermal led to the implementation of many measurements of disinfection and control, which start to show a certain effectiveness on which has occurred of new cases in these establishments, today in clear reduction◊.en
dc.language.isofrfr_FR
dc.publisherEDKfr_FR
dc.relation.ispartofM/S revuesfr_FR
dc.rightsArticle en libre accèsfr
dc.rightsMédecine/Sciences - Inserm - SRMSfr
dc.sourceM/S. Médecine sciences [ISSN papier : 0767-0974 ; ISSN numérique : 1958-5381], 2006, Vol. 22, N° 6-7; p. 601-606fr_FR
dc.subject.meshHumainsfr
dc.subject.meshLégionellosefr
dc.subject.meshAssainissementfr
dc.titleLa légionellosefr
dc.typeArticlefr_FR
dc.contributor.affiliationService des maladies infectieuses et tropicales, Hôpital Bichat, 46, rue Henri-Huchard, 75018 Paris, Francefr_FR
dc.identifier.doi10.1051/medsci/20062267601fr_FR
dc.identifier.pmid16828035fr_FR


Fichier(s) constituant ce document

Thumbnail
Thumbnail
Thumbnail
Thumbnail

Ce document figure dans la(les) collection(s) suivante(s)

Afficher la notice abrégée